Latest Products http://www.servomaxindia.net Latest Products 17-11-23 en-us http://www.servomaxindia.net Electrical Transformers http://www.servomaxindia.net/electrical-transformers.htm Wed, 19 Apr 2017 00:00:00 +0530 Electrical Stabilizers http://www.servomaxindia.net/electrical-stabilizers.htm Mon, 25 Sep 2017 00:00:00 +0530 Power Saver http://www.servomaxindia.net/power-saver.htm Wed, 22 Feb 2017 00:00:00 +0530 In order to keep the quality of the products up to the mark, we check the entire range against varied quality parameters. We ensure on time distribution of wholesale as well as retail consignments owing to an extensive vendor, distributor and logistic facility base.   Salient Features Reduces heat generation in chokes, ballast and prevents energy loss and hazards We can also provide timing profile for enhanced power savings Power savings above 20% in discharge lighting. Uses imported, high quality raw material to get high efficiency of 99.5% Reduction in MDI Improves life of all equipment Uses Isolation shielding to suppress the harmonics and to give quality power to load Reduces maintenance cost up to 80% Eligible for accelerated depreciation benefit Pay back period is 8 to 12 months based on the conditions and usage. Panel Controls & Indications Input Three Phase POWER ON Digital energy meter Improves quality of power and enhances life of electrical gadgets Use latest technology to save power by optimum supply of power to various loads Employs reactive power management system and harmonics filtering system consisting of electronic circuits, special zig - zag inductors, hitech R.C. Circuits and essential switch gear systems Available in four models to suit requirements like lighting, motors, air conditioners and mixed loads Eliminates wastage of power in electrical circuits caused by super imposed power pollution. Protections Overload with MCB / MCCB Manual Bypass provision arrangement Short Circuit with MCB / MCCB Spike, Surges & RF Suppressers Most Suitable for Street Lights / Security Lighting Telecom Buildings Sub-Station Buildings Work Shops Pump Houses Software Units / Call Centers Hotels and Restaurants Commercial Complexes Food Processing units ..... and many more. Automatic Power Factor Control Panel http://www.servomaxindia.net/automatic-power-factor-control-panel.htm Mon, 09 Oct 2017 00:00:00 +0530 As a trusted name, we strictly follow all quality measures and cross check every product at different stages. The company is acknowledged as a reliable name based in Hyderabad(India) and offering products to diverse locations.   Salient Features All major components are of standard make like Siemens, Epcos, L&T and Schneider Microprocessor based automatic controller with power factor display All components are carefully integrated for reliable performance and longer life Capacitor duty Contactors and MCB or MCCB, are used to switch ON capacitors to minimize switching surges Uses small correction steps to maintain accurate setting Auto / Manual Facility, Cooling Facility Very low watt losses In-built time delay for switching ON of a capacitor bank to avoid impulse signal operation. All capacitor feeders have Auto / Manual mode facility with fuse protection and isolation. Details Power Factor Controllers are designed to operate, Automatically with Micro Processor Based Automatic Controller. Use a specially designed electronic control circuit that improves power factor to meet requirements of load switching pattern. Improvement of power factor up to optimum levels is guaranteed. Product range: 20 KVAr to 1000 KVAr. We provide solutions for improving plant power factor by installing our APFC panel. Heavy duty capacitors with detuned filters will be provided where high level non linear harmonies present upto 30%. Advantages Payback period is 8 to 10 months Reduction in maximum demand Energy saving up to 5% Low power factor penalty can be avoided Extended life for Switch Gears, Capacitors and Cables Avoid manual disruptions Avoid high current consumption losses Reduction in Electricity Bill. Most Suitable for Manufacturing Companies BPO Organizations Shopping Malls Steel Mills Spinning Mills Cement and Paper Mills Offices & Buildings Hotel & Restaurants Rice Mills Hospitals Cinema Halls / Multiplexes. <a href="www.servomax.in">more</a> UPS Systems http://www.servomaxindia.net/ups-systems.htm Wed, 20 Sep 2017 00:00:00 +0530 Our clients are most concerned about power issues such as power failure, power sag, power surge, under voltage or over voltage, frequency variation, harmonic distortion and line noise. Servomax emphasizes the areas of redundant power supply, voltage regulation, equipment protection and adjustment.   UPS Systems Feature - The following Leading AC-AC Efficiency Fully redundant design and configuration High input and output power factors Easy expansion without additional hardware Supports to seamless operations at low level of TCO (Total Cost of Ownership). 3 Phase Air Cooled Servo Controlled Voltage Stabilizers http://www.servomaxindia.net/3phase-air-cooled-servo-controlled-voltage-stabilizers.htm Thu, 23 Nov 2017 00:00:00 +0530 Provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipments from high and low voltage. technical specifications input voltage range : 300 - 460v 340 - 480v 360 - 460v ac 3 ph output voltage (3 ph) : 415v ac system : unbalanced 4 wire: r y b n connections : star operating frequency : 47 to 53 hz output voltage adjustable : 380 to 415v ac in 3 ph output voltage regulation : + 1% (no load) output voltage regulation : + 1% (full load) overload capacity : 120% correction rate : 60 30 25v per sec-3 phase waveform distortion : nil output waveform : true reproduction of input insulation : class f short circuit period & percentage : 300% for 250 milli sec. 0 0 normal operation temperature : 0 c to 45 c 0 climate conditions : 90% rh max. Non condensing at 35 c type of cooling : natural air cooled up to 600 kva mode of system : fully automatic system construction : as per is : 9815 â�� 1994 salient features quick response time 10 milli sec (half a cycle) very high efficiency above 98% excellent regulation as high as +- 0.5% micro controllerâ�� controlled system wide input range of operations & high speed of correction metering on lcd display â�¢ 3ph input voltage ph to ph and ph to neutral â�¢ 3ph output voltage ph to ph and ph to neutral â�¢ system frequency â�¢ output current on each ph protections â�¢ single phasing prevention â�¢ output electronic over load protection â�¢ phase reversal protection â�¢ input short circuit protection with mcb â�¢ input over load protection with mcb â�¢ output low voltage protection â�¢ output high voltage protection â�¢ audio alarm for protections indications mains input on 3 led indications 3ph output on indication phase reversal indication over load indication Power Conditioners http://www.servomaxindia.net/power-conditioners.htm Thu, 23 Nov 2017 00:00:00 +0530 Technical Specifications input voltage range - 300 - 460v 340 - 480v 360 - 460v ac 3 ph out put - 415 200v 3ph as per requirement insulation - class h speed of correction - 60 30 25v per sec. With ac motor 105 v sec. With dc motor response time - 10 milliseconds system connections - delta star ratios - 1-1 and 2-1 regulation - better than 3.5 % power factor - 0.75 lead to 0.75 lag di-electric strength - 3kv for 60 sec insulation resistance - better than 1000 mega ohms coupling capacitance - 0.01 pf for 100 db leakage current - less than 20 micro amps common mode attenuation - 100 db 120 db construction standards - as per is 2026 part I & ii type of execution - closed type operating temperature - 0oc to 45oc type of cooling - natural air forced air. High Reliability â�¢ uses solid state control circuits â�¢synchronous motor drive â�¢ no warm - up time â�¢ no relays â�¢professional grade ics and components are used trouble free operation â�¢ quick response time 10 milli sec (half a cycle) â�¢ efficiency, low losses, low temperature rise and withstands in all climatic conditions â�¢ provides perfectly stable output power even under sever conditions of voltage fluctuations â�¢ zero wave - form distortion â�¢ unaffected by load power factor â�¢ ruggedized construction â�¢ enclosure - ip32 â�¢ mounting - floor mounted free on wheel â�¢ servo motor drive - rugged ac step synchronous motor Most Suitable for â�¢ cnc machines â�¢ telecommunication equipments â�¢ bio medical equipments â�¢ large computer installations â�¢ printing machinery â�¢ scientific equipments â�¢ cell phone networks â�¢ garment equipments â�¢ textile machineries .. And many more. Isolation Transformers http://www.servomaxindia.net/isolation-transformer.htm Thu, 12 Oct 2017 00:00:00 +0530 Technical Specifications system connections : delta star input voltage : 415v 3 phase output voltage : 415v or 200v 3 phase ratios : 1:1 and 2:1 regulation : better than 3.5 % power factor : 0.75 lead to 0.75 lag di-electric strength : 3kv for 60 sec insulation resistance : better than 1000mega ohms coupling capacitance : 0.1 pf for 80 db leakage current : less than 20 micro amps common mode attenuation : 80 db 100 db construction standards : as per is 2026 part I & ii, is 11171 type of execution : closed type 0 0 operating temperature : 0 c to 45 c type of cooling : natural air forced air oil cooled (optional) â�¢ eliminates stresses that come from normal electrical transients â�¢ meet stringent clean power requirements of the sophisticated sensitive equipments â�¢ reduces the effects of power line problems like noise, spikes, surges, transients and neutral to minimum Most Suitable For â�¢ cnc machines â�¢ bio medical equipments â�¢ printing machineries â�¢ cell phone networks â�¢ scientific equipments â�¢ textile machineries â�¢ oil & vanaspathi plants â�¢ large computer installations â�¢ garment equipments .. And many more. K-Rated Transformers http://www.servomaxindia.net/k-rated-transformers.htm Mon, 13 Nov 2017 00:00:00 +0530 Technical Specifications Transformer â�¢ Double wound , High Isolation â�¢ Double sized neutral â�¢ Insulation class â��Hâ�� â�¢ Regulation is better than 3.5% â�¢ Overload rating of 100% for 10 secs â�¢ Core of CRGO and conductor of copper â�¢ Natural / Forced Air Cooled â�¢ As per IS:2026 standards â�¢ Attenuation: 80 db/100 db CMRR â�¢ Primary connect as DELTA, secondary connection as STAR â�¢ Efficiency of the transformer is minimum 98% K-Rated Isolation Transformer is to deliver conditioned power to a nonlinear highharmonic current load and operate at safe temperatures while minimizing the harmonic currents. In a data centre, all the distributed power loads are connected through a non linear power source, due to which HARMONICS generation is unavoidable. These generated Harmonics are flow back and directly effects the mains power source, which a UPS. The effect of harmonics de-rates the capacity of UPS. Hence 100% utilization of UPS capacity becomes wasted. The effect of harmonics also creates much heat in the transformers of UPS. To eliminate these direct effects on UPS, K-Factor Transformers are designed based on the harmonics present the load. The special design of K-Factor Transformer helps us to depend on much to eliminate or withstanding from the effects of Harmonics. LT Panels http://www.servomaxindia.net/lt-panels.htm Fri, 17 Nov 2017 00:00:00 +0530 General Features  L.V Switchboard  As per IS Standards  IP 52 / 54 / 55 protection  Indoor / Outdoor  Electrolytic Busbars Aluminium / Copper  Customized Panels  Single Front / Double Front / Dead Front  DMC / SMC Insulators  Capacity Expandable  Complete Earthing of Doors & Frame  Shipping sections as per demand Products  Power Control Centres (PCC) Panels  PMCC Panels  Motor Control Centres (MCC) Panels  Automatic Power Factor Control (APFC) Panels  Power Distribution Boards (PDB)  Sub Distribution Boards  Main Lighting Distribution Boards (MLDB)  Sub Lighting Distribution Boards  Control Desks  Feeder Pillars  Non – Segregated LT Busducts Product Special Features  SMS facility for Energy Reading & Low Power Factor  Earth fault relay  Phase Sequence indication